| The wind transmitters are equipped with a contact-free opto-electronic scanning system which causes an extremely low starting speed. | ||
Order-No. |
||
4.3303.22.0XX |
Measuring range |
0,3 ... 50 m/s |
.6XX |
0,3 ... 60 m/s | |
.X00 |
Electrical output |
3 ... 1042 Hz (live zero) |
.X07 |
3 ... 1042 Hz (no live zero) for datalogger | |
.X40 |
0 ... 20 mA | |
.X41 |
4 ... 20 mA | |
.X60 |
0 ... 1 V | |
.X61 |
0 ... 10 V | |
.X73 |
0 ... 5 V | |
| Starting velocity | 0,3 m/s | |
| Max. stress | 60 m/s | |
| Accuracy | ± 0,4 m/s bzw. 2,5% of meas.value | |
| Resolution | 0,05 m wind run | |
| Wind load at 35 m/s | approx. 10N | |
| Distance constant | 5 m | |
| Ambient temperature | -35 ... +80°C | |
| Operating voltage | With heating | 24 V AC/DC approx. 20W, electronically regulated |
| W/o heating | 15 - 24 V DC | |
| Connection | 5 pole plug connector in the shaft | |
| Mounting | Onto mast tube 1 ½”, for ex. DIN 2441 | |
| Weight | 1 kg | |
| This measuring value transmitter is equipped with a DC-generator, which generates DC-voltage on rotation of the cup star. A display instrument, for ex., can be operated directly (without power supply). | |
Order-No.: 4.3105.22.000 |
|
| Measuring range | 0,5 ... 35 m/s |
| Electr. output | 0 ... 4,67 mA DC, linear Ra = 400 ohms |
| Stress | max. 60 m/s |
| Distance constant | 5 m |
| Accuracy | Hz-output : ± 0,3 m/s, ± 2% of meas. value |
| mA, V-output: ± 04 m/s, ± 2,5 % of meas. value | |
| mA, DC-output: ± 0,5 m/s, ± 2% of meas. value | |
| Operating voltage | 4…18 V DC; Hz-output |
| 14…18 V DC; mA/-output | |
| 24 V AC/DC; with heating | |
| Ambient temp. | -35 ... +80°C |
| Heating | max. 20 W |
| Electr. connection | 5 pole plug connector |
| Mounting | onto mast tube 1 ½ “ acc. to DIN 2441 |
| Fixing boring | Ø 50 x 50 mm |
| Dimension | Ø 315 x 230 mm |
| Weight | 1 kg |