The Datalogger DL16 is a complete measuring system for automatic acquisition and storing of meteorological and environmental measuring data.
| Technical Data | |
| The standard measuring value inputs of the DL16 | • 6 x 32bit counter for all THIES anemometers with broken wire detection • 6 x serial-synchronous for all THIES wind direction sensors • Event counter for precipitation • Up to 16 PT 100 inputs • Up to 16 0-100 mV inputs (e.g. for radiation) • Up to 16 0-1 V inputs • Up to 16 0-10 V inputs • Up to 16 0/4-20 mA inputs • 6 serial interfaces RS232, RS422, RS485, USB • 4 high-current switch 60 V DC, 48 V AC • 1 high-current measurement channel AC, DC galvanically decoupled 1A • 1 high-current measurement channel AC, DC galvanically decoupled 10A • base for modem module analogue, ISDN, GSM, GPRS external |
| Further Thies sensors connectable to the RS485 bus | • THIES Laser Precipitation Monitor LNM • THIES Ultrasonic- Anemometer 1D / 2D / 3D • THIES FIRST CLASS wind direction - wind velocity transmitter • THIES Sensor-Interfaces (up to 5 possible) |
| A/D transformer RTC real time clock |
Max. 24 bit resolution with differential inputs Temperature compensated RTC |
| Time synchronization | DCF77 via external antenna or NTP via Ethernet |
| Measuring cycle | 0.25 sec for wind values configurable 1 sec. ... 60 min. for each measurement channel |
| Data storing | Storage of data in any archives. Archive values are grouped. Storage interval settable |
| Power supply -Accumulator -Solar-panel -Buffer battery -Mains operation |
12 V / 7 Ah voltage monitoring 22 V idling voltage, 17 V nominal voltage, arbitrary power charging current 2 A max. Lithium cell for buffering of data and time 230 V / 115 V / 300 VA monitored mains status |
| Operating Temperature Housing Protection |
-30 ... +60 °C Stainless steel IP 65 |
|
|